A Firestop plate is used to allow the chimney to pass between floors, for example, when you need the chimney to go through the ceiling on the ground floor through to the first floor. The steel plate is designed to provide the appropriate distance between the flue and the adjacent flammable materials, according to both fire and building regulations. A plate must be used top and bottom of the floor penetration.
A ventilated firestop plate (T600) can be used on installations burning all fuels. All TWPro fire stops are set at a 50mm to combustible distance.
TWPro is HETAS Approved and is CE marked. Designation Number is EN1856-1 T600 N1 W V2 L50040 G50. EN1856-1 T200 P1 W V2 L50040 O20.
System: TWPro Black
Inner Material: 316L Stainless Steel – 0.40mm thick
Outer Material: 304 Stainless Steel – 0.40mm thick – High Temperature Black Coated
Fuels: Wood, Oil, Gas, Low sulpher coal
Approvals: HETAS / CE
Distance to Combustibles: 50mm
Flue Options
Flue Size 5″ (127mm) internal and 7″ (175mm) external
Flue Size 6″ (152mm) internal and 8″ (202mm) external
Stainless Steel or Matt Black
Only use 5″ flue pipe on a DEFRA approved stove with a 5″ vitreous flue pipe connection all other must be 6″ to comply with regulations
Phone
01773 718718
Email
sales@castfireplaces.co.uk
Reviews